SBV Journal of Basic, Clinical and Applied Health Science

Register      Login

VOLUME 4 , ISSUE 4 ( October-December, 2021 ) > List of Articles

SHORT COMMUNICATION

Methods to Extract the Materials Trapped in the Needle Hub during Fine Needle Aspiration Cytology Technique

Jackson Bose, Dost M Khan, Adayalam Chandana

Keywords : Fine needle aspiration cytology, Material trapped in needle hub, Unsatisfactory smear

Citation Information : Bose J, Khan DM, Chandana A. Methods to Extract the Materials Trapped in the Needle Hub during Fine Needle Aspiration Cytology Technique. 2021; 4 (4):90-91.

DOI: 10.5005/jp-journals-10082-03124

License: CC BY-NC 4.0

Published Online: 24-12-2021

Copyright Statement:  Copyright © 2021; The Author(s).


Abstract

The incidence of getting an unsatisfactory smear while performing fine needle aspiration cytology is high when performed with the needle alone and when only limited material is obtained during the procedure. This reflects in the adequacy of material obtained and also creates confusion for the reporting cytopathologist. A major problem arises when most of the material that is obtained during a needle biopsy is trapped within the needle hub. This invasive procedure is generally done by the surgical pathologist, and it involves great skills and techniques to perform and also obtain adequate material from the hub of the needle. The material obtained during the procedure plays a vital role in obtaining a satisfactory smear and reduces the confusion during reporting. Thus, to obtain the material from the needle hub that is trapped, certain methods can be followed so that it helps in obtaining adequate material as well as reduces the needle passes given to the patient during the procedure.


HTML PDF Share
  1. Pennes DR, Naylor B, Rebner M. Fine needle aspiration biopsy of the breast. Influence of the number of passes and the sample size on the diagnostic yield. Acta Cytol 1990;34(5):673–676.
  2. Boerner S, Sneige N. Specimen adequacy and false-negative diagnosis rate in fine-needle aspirates of palpable breast masses. Cancer Cytopathol 1998;84(6):344–348.
  3. Lee HC, Ooi PJ, Poh WT, Wong CY. Impact of inadequate fine-needle aspiration cytology on outcome of patients with palpable breast lesions. Aust N Z J Surg 2000;70(9):656–659. DOI: 10.1046/j.1440-1622.2000.01920.x.
  4. Snead DR, Vryenhoef P, Pinder SE, Evans A, Wilson AR, Blamey RW, et al. Routine audit of breast fine needle aspiration (FNA) cytology specimens and aspirator inadequate rates. Cytopathology 1997;8(4):236–247. DOI: 10.1046/j.1365-2303.1997.8682086.x.
  5. Lazda EJ, Kocjan G, Sams VR, Wotherspoon AC, Taylor I. Fine needle aspiration (FNA) cytology of the breast: the influence of unsatisfactory samples on patient management. Cytopathology 1996;7(4):262–267. DOI: 10.1046/j.1365-2303.1996.40782407.x.